The first steps of this lesson
Step 1: What a Glovebag Can and Cannot Cover
Title 8 section 1529(g)(5)(B) allows glove bag systems to remove PACM or ACM from straight runs of piping and from elbows and other connections. Section 1529(b) defines a glovebag as an impervious plastic bag-like enclosure affixed around not more than a 60 x 60 inch asbestos-containing material, with glove-like appendages through which material and tools are handled. The same section limits "disturbance" to the amount one glove bag or waste bag can hold, and in no event more than a bag not exceeding 60 inches in length and width. That 60 inch limit is how you count bags.
Step 2: The Bag Itself
Section 1529(g)(5)(B)1 requires glovebags of 6 mil thick plastic that are seamless at the bottom. Bags used on elbows and other connections must be designed for that purpose and used without modification. A negative pressure glove bag adds a HEPA vacuum or similar device attached to the bag to prevent collapse, and that unit must run continuously until the work is done, when the bag is collapsed before it is removed from the pipe (g)(5)(C).
The remaining 3 steps, the worked example and the quiz are in the course. This is a preview. The full lesson, with the step-by-step explanations, a worked example and a quick-check quiz, is inside the classroom.
Independent exam preparation. Contractors Classroom is not affiliated with the Contractors State License Board, and no course can guarantee a passing result.