The first steps of this lesson
Step 1: What a PCM Count Measures and What It Is Compared To
Title 8 section 1529(b) defines a fiber as 5 micrometers or longer with a length-to-diameter ratio of at least 3 to 1, and that is what the phase contrast microscope (PCM) analyst counts (Appendix A, item 13). Section 1529(c) sets the permissible exposure limit at 0.1 fiber per cubic centimeter as an 8-hour time-weighted average and the excursion limit at 1.0 fiber per cc over a 30-minute sample, both measured by the Appendix A method or an equivalent. Section 1529(f)(2)(B) tells you that on Class I work you presume exposure is above both limits until monitoring or a negative exposure assessment shows otherwise.
Step 2: Collect the Sample Correctly
Appendix A to section 1529 calls for a new 25-mm cassette with an open-faced 50-mm extension cowl, a flow rate between 0.5 and 2.5 liters per minute, pumps calibrated before and after use, and the sample taken in the employee's breathing zone (items 2, 3, 6, 7). Each set includes 10 percent field blanks or a minimum of 2 (item 11). The non-mandatory Appendix B suggests at least 25 liters for a TWA sample and 48 liters for a 30-minute excursion sample (5.2.7), and no more than about 100 liters where visible dust is present or 240 liters with little dust, to avoid overloading the filter (5.2.8). Air volume is flow rate times minutes.
The remaining 3 steps, the worked example and the quiz are in the course. This is a preview. The full lesson, with the step-by-step explanations, a worked example and a quick-check quiz, is inside the classroom.