The first steps of this lesson
Step 1: Treat Every Overhead Line as Live
Cal/OSHA's tree-work rules start with training: workers near electrical equipment and conductors must be instructed to consider all of it energized with potentially fatal voltages, never to touch it directly or indirectly, and to understand that shock can come from contact with a conductor, an energized limb, a tool, or a grounded object, or from step potential near a downed conductor (8 CCR Sec. 3423(a)). Under the electrical orders, an overhead conductor is considered energized unless and until the owner verifies it is not and it is visibly grounded at the work site (8 CCR Sec. 2946(d)). Wet or contaminated rope that is not insulating for the voltage must not be used near exposed energized lines (8 CCR Sec. 2951(i)(2)).
Step 2: The 10-Foot Rule for High Voltage
Employees shall not perform tree trimming within 10 feet of high-voltage energized power lines unless they meet the line-clearance requirements (8 CCR Sec. 3423(b)(1)). The tree-work standard defines 'Proximity' as within 10 feet of overhead conductors rated 50 kV phase to phase or less; above 50 kV the distance grows 4/10 inch (10 mm) for each additional kV (8 CCR Sec. 3420(b)). The High-Voltage Electrical Safety Orders print the minimum approach distance for persons other than qualified line-clearance tree trimmers in Table 1 of Sec. 2950: 10-00 for 0.0 to 50.0 kV, 10-09 for 50.1 to 72.5 kV, 12-04 for 72.6 to 121.0 kV, and 13-02 for 138 to 145 kV.
The remaining 3 steps, the worked example and the quiz are in the course. This is a preview. The full lesson, with the step-by-step explanations, a worked example and a quick-check quiz, is inside the classroom.
Independent exam preparation. Contractors Classroom is not affiliated with the Contractors State License Board, and no course can guarantee a passing result.