The first steps of this lesson
Step 1: Why Roofers Care About Attic Vents
Enclosed attics and enclosed rafter spaces must have cross ventilation through openings protected against rain and snow (2025 California Residential Code R806.1; 2025 California Building Code 1202.2.1, with 1503.4 sending roof vent intake and exhaust to 1202.2). The roofer usually installs the ridge, box, and soffit vents, so the roofer is the one who has to size and count them. Unvented attics are a separate design allowed under CRC R806.5 and CBC 1202.3 when the attic is inside the thermal envelope and the listed conditions are met.
Step 2: Net Free Area Is What Counts
The code sizes vents by net free ventilating area (NFA), the area air can actually pass through after louvers and screens are subtracted. It is printed on the vent label in square inches per vent or per lineal foot, so never use the outside size of the vent. Openings must have a least dimension between 1/16 inch and 1/4 inch, or be covered with corrosion-resistant wire cloth screening, hardware cloth, or perforated vinyl with 1/16 to 1/4 inch openings, so birds, rodents, and snakes cannot get in (CRC R806.1; CBC 1202.2.2).
The remaining 3 steps, the worked example and the quiz are in the course. This is a preview. The full lesson, with the step-by-step explanations, a worked example and a quick-check quiz, is inside the classroom.