Step 1: A Permit Pulls the Whole House Up to New-Dwelling Smoke Alarm Rules
Under 2025 California Residential Code (CRC) R310.2.2, where alterations, repairs or additions requiring a permit occur, the individual dwelling unit must be equipped with smoke alarms located as required for new dwellings. Carbon monoxide alarms have their own triggers: R311.2.1 requires them in dwelling units that contain a fuel-fired appliance or fireplace, or have an attached garage with an opening into the dwelling, and R311.2.2 requires new CO alarms when an addition is made or a fuel-burning heater, appliance or fireplace is added. Exterior-surface work (roofing, siding, windows and doors, a porch or deck) and plumbing work are exceptions in R311.2.2 (and in the interconnection and power rules). Plan the alarms in the estimate, because the inspector will count them.
Step 2: Where Smoke Alarms Go (R310.3)
R310.3 requires smoke alarms in each sleeping room, outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling unit, including basements and habitable attics but not crawl spaces or uninhabitable attics. R310.3 also keeps alarms at least 3 feet horizontally from the door of a bathroom with a tub or shower unless that would prevent placing a required alarm. A hall alarm on a level counts as that level's alarm, so you only add a separate alarm on a story that has neither a bedroom nor a sleeping-area hall.
The remaining 3 steps, the worked example and the quiz are in the course. This is a preview. The full lesson, with the step-by-step explanations, a worked example and a quick-check quiz, is inside the classroom.
Independent exam preparation. Contractors Classroom is not affiliated with the Contractors State License Board, and no course can guarantee a passing result.